Komatsu — EVERY 1000 HOURS SERVICE

d. TURBOCHARGER ROTOR PLAY Contact your Komatsu distributor for checking, or proceed as follows: Remove air intake and exhaust pipes from turbocharger. 1. Axial play Check axial play by moving rotor in axial direction. Play: Standard 2. Radial play 0.025 to 0.100 mm Measure radial play by moving rotor holding both ends by hands in radial direction in parallel. Play: Standard 0.075 to 0.180 mm t If the play is over the limit, consult your Komatsu distributor. * If the rotor is excessively soiled with dust or carbon or if any oil leakage caused by turbocharger trouble is noted, have the turbocharger repaired by your Komatsu distributor. e. CORROSION RESISTOR 1.

Screw in valves (1) at the top of the corrosion resistor. 2. Using a filter wrench, turn cartridge (2) counterclockwise and remove it. 3. Coat the seal surface of the new cartridge with engine oil. t Bring the packing surface into contact with the seal surface of the filter holder, then tighten a further 2/3 turns. 4. Open valves (1). * Use a genuine Komatsu cartridge. 5. Start the engine and check that there is no leakage of water from the seal surface. -140-