Komatsu — WHEN REQUIRED

WHEN REQUIRED a. CLEAN INSIDE OF COOLING SYSTEM Clean the inside of the cooling system, change the coolant, and add the corrosion resistor agent KI, or replace the corrosion resistor cartridge equipped), according to the table. (if Stop the machine-on level ground when cleaning or changing the coolant. Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. In areas where the water is hard, always add genuine Komatsu anticorro- sion agent KI. (One packet of corrosion resistor agent KI contains 1009.

The standard density of the mixture should be 7g/P.) If a corrosion resistor cartridge is installed, always replace it. Use city water for the cooling water. If river water, well water or other such water supply must be used, con- tact your Komatsu distributor. A Antifreeze is flammable, so keep it away from any flame.

Cleaning inside of Adding corrosion resistor Kind of coolant cooling system and agent KI or replacing changing coolant corrosion resistor cartridge Permanent type antifreeze (All season type) Every year (autumn) or every 2000 hours whichever comes first Non permanent type Every 6 months (spring, antifreeze containing autumn) ethylene glycol (Drain antifreeze in spring, (Winter, one season type) add antifreeze in autumn) Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant Every 6 months or When not using antifreeze every 1000 hours whichever comes first - 148-