EXPLANATIONS OF COMPONENTS 1. PUMP SELECTOR SWITCH This is the switch to select one pump or two pumps. When installing attachments that require speed (crushers, etc.) set to the 2-pump position (a), and when installing the attachment do not require speed, set to the l-pump position (b). * When installing a bucket, set to the l-pump position. (f): Front of machine 2. CONTROL PEDAL This is used to operate the attachment. * * When the pedal is depressed, the attachment is actuated. For details of the oil flow, see HYDRAULIC CIRCUIT. Please follow the precautions for handling the attachment given in the operation manual provided by the attachment maker.
When general attachments are not installed, if the pedal is installed, it will cause overheating. (f): Front of machine * 3. FUSES Fuse capacity and the name of circuit * There are two 1 OA fuses and one 15A fuse provided as spare fuses. No.
Fuse cananitv Name of circuit Remarks 0 IOA Pump controller, solenoid valve - 0 IOA Engine governor controller - 0 IDA Monitor, buzzer - 0 15A Heater (air conditioner, cooler) - 0 15A Right head lamp, working lamp (additional front lamp) - @ IOA Room lamp, radio, cigarette lighter - 0 10A Wiper motor, horn (Window washer) - @ IOA Room lamp, clock - @ IOA Battery relay, preheating heater relay, starting signal - @I IOA I-pump/2-pump selector switch, solenoid - - 186-