Komatsu — PC200, 200LC-5 MIGHTY (METHOD FOR HANDLING THE ATTACHMENTS)

HYDRAULIC CIRCUIT A.SWlTCHlNG HYDRAULIC CIRCUIT When installing an attachment or installing a bucket, set left and right 3-way valves (1) installed to the hydraulic circuit as follows. Match the attachment and the direction of left and right 3-way valves (1) as shown in the table below. (The arrow showing the direction of the port is stamped on the head of the 3-way valve. In the case of the breaker, set the direction of the arrow to “B”, and in the case of crusher, set it to “C”.) Crusher, etc. 1 Front oGchine / Front ogzine * Switch the direction of the 3-way valve port as follows. Using a wrench, turn rotor (A) to the end of its stroke.

+r When installing a breaker, connect the return circuit directly to the return filter. * The standard set pressure for the low pressure safety valve is set as 210 kg/cm2 when shipping from the plant. When installing breakers made by other manufacturers, it is necessary to adjust the pressure, so please contact your Komatsu distributor. - 188-