C. PATH OF OIL FLOW The direction of operation of the pedal and the flow of oil is as shown in the diagram. -Hydraulic circuit when crusher is installed ----Hydraulic circuit when breaker is installed -----. Pilot circuit --Electrical circuit b When rear of pedal is depressed b When front of pedal is depressed * When the breaker is being used, no oil will flow when the rear of the pedal is de- pressed. 1. Circuit connected directly to oil 7. cooler (selection possible by 3-way valve) 8. 2. Additional filter 9. 3. Oil cooler 10. 4. Main filter 11. 5. Hydraulic pump 6. Hydraulic tank 12.
Control valve Solenoid valve Control pedal Selector switch Low pressure safety valve circuit (Selection possible by 3-way valve) Stop valve D. HYDRAULIC SPECIFICATIONS . Max. flow when merged: 191 X 2 Urnin * Main relief set pressure: 325 kg/cm2 (when pressure rises: 340 kg/cm*) . Safety valve set pressure: 175 - 365 kg/cm2 E. OPERATION OF PEDAL When the pedal is pressed to the front, neutral, or rear, the movement of the attachment is as follows. . Hydraulic breaker Scrap grapple bucket Front: Actuated Neutral: Stop Front: Grip Neutral: Hold Rear: Stop Rear: Release - Power ripper Front: Dig in TS crusher Front: Bite Neutral: Hold Neutral: Hold Rear: Release Rear: Remove - Fork grab Front:
Grip Hydraulic pile driver Front: Grip Neutral: Hold Rear: Release Neutral: Hold Rear: Release . Grapple bucket Hydraulic excavator with multi-purpose crane Front: Grip Neutral: Hold Front: Wind in Neutral: Hold Rear: Release Rear: Wind out - 192 -