PROCEDURE FOR REMOVAL AND INSTALLATION OF ATTACHMENT PROCEDURE FOR.REMOVAL 1. 2. Lower the attachment to the ground and stop the engine. After stopping the engine, operate each control lever and attachment control pedal to the front and rear, and left and right 2 or 3 times to the end of its stroke to release the remaining pressure inside the hy- draulic circuit. 3. After checking that the oil temperature is low, turn the rotor of the stop valves installed to the inlet and outlet piping at the side of the arm to the OFF position. Remove the hose from the attachment, then install blind covers to the inlet port and outlet port (2 places).

The blind covers are to prevent defective actuation of the attachment caused by the entry of dirt or dust, so fit them securely before storing the parts away. Pull out the mounting pins (2 places), remove the attachment, then in- stall the bucket. For details of the procedure for installing the bucket, see INVERSION AND REPLACEMENT OF BUCKET in the operation manual for the stan- dard machine. 6. After installing the bucket, check the oil level in the hydraulic tank. 4. * 5. * -194-