Komatsu — OPERATING THE AIR CONDITIONER (EXCEPT PC200, 200LC-5 MIGHTY)

INSPECTION AND MAINTENANCE A. Clean air filter If the air filter inlets is clogged, the heating or cooling capacity will drop. Clean the air filter with compressed air once a week. B. Check tension of compressor belt. If the belt is loose, it will slip and the air conditioner will not be able to cool properly. Periodically press the mid-point of the belt with the finger and check that the deflection is 15 to 18 mm. When the belt is new, it is particularly liable to stretch, so always adjust it after 2 to 3 days. (a): Compressor pulley (b): Drive pulley C. Check volume of refrigerant (gas) If there is a lack of refrigerant, the cooling performance will be poor.

When operating the cooler at high speed, there should be no bubbles in the sight glass (inspection window) mounted on the condenser unit receiver. If there are any bubbles, there is a lack of gas, so have to add refrige- rant at a shop. (a): Sight glass (b): No refrigerant (c): Lack of refrigerant (d): Correct amount of refrigerant A The refrigerant used in the cooler is colorless and odorless, and is harmless when released into the atmosphere. However if it gets in the eyes or on the hands, it will be cause of burn or loss of sight, so never loosen any part of the refrigerant circuit. D:

Check during off-season When the air conditioner is not being used, run the compressor at low speed for a few minutes every week to avoid loss of oil. (Run the engine at low speed with the cooler temperature regulator knob at LOW COOL.) * In cold weather, do not run the compressor suddenly at high speed. This may cause failure in the compressor. When the temperature is below 2 to 6.5X, the low pressure cut-off switch functions to ‘stop the compressor from running even when the air conditioner switch is pressed. - 34 -