Komatsu — HANDLING HYDRAULIC SYSTEM

OUTLINE OF SERVICE MAINTENANCE HANDLING HYDRAULIC SYSTEM G The hydraulic equipment is at high temperature during operations or after completion of operations. In addi- tion, it is also under high pressure during operations, so pay careful attention to the following points when car- rying out inspection and maintenance of the hydraulic system and components. G Stop the machine on level ground, lower the dump body, and take action to ensure that no pressure is applied to the cylinder circuit. G Always stop the engine.

G Immediately after stopping operations, the hydraulic oil and lubricating oil is at high temperature and high pressure, so wait for the temperature at all parts to go down before starting maintenance. Even when the temperature goes down, some parts may be under internal pressure, so when loosening plugs, threads, or hose connections, do not stand immediately in front of the part. Loosen the parts slowly to release the internal pressure before removing them. G When carrying out inspection and maintenance of the hydraulic circuit, always release the air from the hydraulic tank to remove the internal pressure.

G Inspection and maintenance includes inspection of the hydraulic oil level, replacement of filters, and changing the hydraulic oil. G When removing high-pressure hoses, check that there is no damage to the O-ring. If any damage is found, replace. G If the hydraulic filter element, strainer, or other parts have been replaced or washed, or if any hydraulic equip- ment has been repaired or replaced, or hydraulic piping has been removed, it is necessary to bleed the air from inside the circuit. 4-8