Every 4000 Hours Service MAINTENANCE Maintenance for every 50, 100, 250, 500, 1,000, and 2,000 hours service should be performed at the same time. Lubricating Carry out the greasing once every two years, regardless of whether the 4,000 hour interval has passed. If you fail to grease the drive shaft, the shaft will break. There is a danger that the broken shaft will cause serious damage to the machine. To avoid this problem, always maintain the specified greasing interval strictly. If special drive shaft grease is used, carry out greasing every 4,000 hours or every two years. When the special grease is not used but the normal lithium-based grease is used, carry out greasing every 1,000 hours.
Required 1. Stop the engine and set the parking brake switch to the ON position (A). 2. Stop the machine so that the drive shaft is in the position so that the grease fitting of center drive shaft spline (1) is as shown in the figure and you can supply grease from under the machine. At this time, the grease fitting is at the position indicated by the arrow at the circle below, seen from the rear of the machine. All graphic views are from the rear of the machine. 3. Using a grease pump, pump in grease through the grease fittings marked by the arrows. 4. After greasing, wipe off any old grease that was pushed out. (1) Center drive shaft spline (1 place) WA430-6 3-89