Komatsu — Checks Before Starting

MACHINE OPERATIONS AND CONTROLS OPERATION 5. Extend the boom, arm, and bucket cylinder fully as shown in the diagram on the right, remove the oil filler cap, then install the cap and pressurize the inside of the tank. NOTICE Be sure to pressurize the hydraulic tank. If it is not pres­ surized, the pump will suck in air, and this will adversely affect the equipment. Check Dust Indicator 1. Open the engine rear cover and cooling cover. For details, see Section “COOLING COVER (3-30)“. 2. Check that the red piston has not appeared in the transpar­ ent portion of dust indicator (1). 3. If the red piston has appeared, clean or replace the ele­ ment immediately.

For details of the method of cleaning the element, see “CHECK, CLEAN AND REPLACE AIR CLEANER ELE­ MENT (4-20)“. 4. After checking, cleaning, and replacing, press the knob of dust indicator (1) to return the red piston to its original posi­ tion. 3-46