MAINTENANCE MAINTENANCE PROCEDURE BLEEDING AIR FROM HYDRAULIC SYSTEM 4 NOTICE If the pump is operated without filling the pump case with hydraulic oil, there is danger that the pump may be prematurely damaged. Be sure to bleed the air completely. 1. Bleeding air from piston pump 2. Remove 3 M10 bolts (1), then remove triangular cover (2). 3. Remove the oil filler cap from the hydraulic oil tank. 4. Loosen air bleed plug (3) and check that oil oozes out from the bleeder plug (completion of air bleeding). 5. After completion of the air bleeding operation, tighten the air bleed plug. 6. Tighten the oil filler cap of the hydraylic oil tank. 7. Install the cover. 8. Start the engine.
For details, see “STARTING ENGINE (3-54)“. Run the engine at low idling for 10 minutes, then do as follows. 9. Bleeding air from cylinders NOTICE If the engine is run at high speed immediately after startup or a cylinder is pushed up to its stroke end, air taken inside the cylinder may cause damage to the piston packing. 10. Run the engine at low idling, and extend and retract each cylinder 4 to 5 times, taking care so that a cylinder may not be brought up to its stroke end. (Stop the cylinder approx. 100 mm (3.9 in) short of its stroke end) 11. Next, operate each cylinder 3 to 4 times to the end of its stroke. 12.
Finally, operate each cylinder 4 to 5 times to the end of its stroke to completely remove the air. 4-43