N40469 Chapter 5 How to check the condition of the heat exchanger The interval for the maintenance of the tube type heat exchanger (figure 13 item 1) depends on the operating environment of the vessel and on the operating time. The sea water that is circulated through the heat exchanger and the amount of operating time of the vessel affects the following items: • Cleanliness of the tubes for the heat exchanger • Effectiveness of the heat exchanger system Operating in water that contains silt, sediment, salt, algae, etc will adversely affect the heat exchanger system. In addition, intermittent use of the vessel will adversely affect the heat exchanger system.

Figure 13 The following items indicate that the heat exchanger may require cleaning: • Increased coolant temperature • Engine overheating • Excessive pressure drop between the water inlet and the water outlet An operator that is familiar with the normal operating temperature of the coolant can determine when the coolant temperature is out of the normal range. Inspection and maintenance of the heat exchanger are required if the engine is overheating. Figure 14 Cleaning the Heat Exchanger 1. Drain the fresh water and auxiliary water circuits. 2. Undo the hose clips (figure 14 item 1). 3. Remove bolts (figure 14 item 2). 4. Remove the heat exchanger. 5.

Remove the endcap by undoing the bolts (figure 15 item 1). 6. Turn the heat exchanger core upside-down in order to remove debris. Note: Do not use a high concentration of caustic cleaner to clean the core. A high concentration of caustic cleaner can attack the internal metals of the core and cause leakage. Only use the recommended concentration of cleaner. Figure 15 Page 33