Industrial — Electrical System

ELECTRICAL ELECTRICAL Low Voltage Disconnect (LVD) Electrical System Purpose See an authorized dealer if the LVD fails to reconnect loads during normal operation. WARNING! The LVD may increase battery life and prevent unnecessary jump start conditions by ensuring that an unattended load does not deplete the battery charge to a level that will prevent you from starting your vehicle. Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Wash hands after handling.

Circuits Disconnected By LVD Cab Dome Lamps Cab Accessories Operation Spare Battery A and B CAUTION The LVD will disconnect non-vital battery loads when battery voltage drops below 12.3V for 3 minutes and the key switch is in the ACC or OFF position. During the last 2 minutes the LVD will emit a slow audible beep. 30 seconds before disconnecting loads the alarm will change to a fast beep. The battery voltage must come back up above a certain voltage before the LVD will reset. NOTE Do not modify or improperly repair the vehicles electrical system or power distribution box. All electrical repairs should be performed by an authorized dealer.

Improper repair or modifications will void your war- ranty and/or cause serious damage to your vehicle. All LVD circuits are color-coded blue on the central electrical panel cover label. 5 (03/17) Y53-6077-1B1 5-87