MAINTENANCE - Electrical System audible beep. After 2 minutes of flashing the warning on the DPC, the LVD will shut- off any circuit connected through the LVD system. Even if the ignition switch is cycled OFF and ON again, the LVD will continue to fault until it sees battery voltage at, or above, 12.2V. WARNING! Do not use the Spare Battery A and B cir- cuits or other circuits that are controlled by the LVD to power electronic engine controls, ABS circuits, or safety/work related lighting. Before adding any device to the vehicle's electrical system, consult your nearest au- thorized dealer or read the contents of TMC RP136.
Failure to do so may cause equip- ment damage or lead to personal injury. Circuits Disconnected By LVD Cab Dome Lamps Cab Accessories Spare LVD wiring for customer added accessories 5 NOTE All LVD circuits are color-coded blue on the central electrical panel cover label. The LVD will disconnect non-vital battery loads when battery voltage drops below 12.2V for 2 minutes and the key switch is in the ACC or OFF position. During the next 30 seconds, the LVD will flash the Battery Disconnect Telltale in the Driver Information Display. As the telltale flashes an audio warning will also sound.
During the last 2 minutes the LVD will emit a slow Y53-6096-1A1 (01/17) 177 NOTE The determination of what circuits/loads that were connected to the LVD was based upon the recommendation from Technology and Maintenance Council (TMC) of the Ameri- can Trucking Association. To review the rec- ommended practice, see TMC RP-136.