Yamaha Motor Co., Ltd. VK540E — Yamaha Motor Co., Ltd. VK540E User Manual

BATTERY Inspection 1. Inspect: Battery fluid level Below lower level Refill. 1 Upper level 2 Lower level 2. Check: Specific gravity Less than 1.280 Recharge battery. Battery Storage The battery should be stored if the vehicle is not to be used for a long period. 1. Remove: Battery Battery storage and maintenance tips: Recharge the battery periodically. Store the battery in a cool, dry place. Recharge the battery before reinstalling. CHARGING COIL 1. Measure: Charging coil resistance Out of specification Replace. Charging coil resistance: (White – Black) 0.4 Ω ± 20% at 20 (68 F) 7-26 CHARGING SYSTEM ELEC Battery Electrolyte Specific gravity: