MAN Nutzfahrzeuge Aktiengesellschaft — Engine start / stop: bridge / flybridge

Engine start / stop: bridge / flybridge The engine should be started and also stopped in the normal way using the ignition switch. Connect this up via terminal 15 and terminal 30 (+). Fig. Kl. 30 Ignition lock / stop Ignition lock / stop 30 30 15 50 15 50 Kl. 15 Kl.50g Terminal box No separate stop switch should be installed apart from the ignition lock and the emergency stop button. Stopping the engine: normal procedure 1. Turn ignition key from position 1 position 0 Engine stops 2.

Switch off battery main switch If this procedure is not adhered to and the battery main switch is switched off before the ignition, fault entries may be made in the EDC fault memory and the engine speed will be reduced. Reason: The voltage supply to the control unit will be interrupted as the EDC tracks. 93