Komatsu — Check, clean, or replace air cleaner element

MAINTENANCE Service procedure When required 4. Clean the interior of the air cleaner body, cover (3) and evacuator valve (6). NOTICE The inner element must not be used again even after its cleaning. When replacing the inner element, replace the outer element at the same time. 5. Direct dry compressed air (Max. 0.69 MPa (7 kgf/cm2, 99.4 PSI)) from the inside of the outer element along its folds. Then direct the compressed air from the outside along the folds, and again from the inside. Replace any outer element, which has been cleaned 6 times or used for one year. Replace the inner element at the same time.

Replace both inner and outer elements when the dust indicator red piston appears soon after installing the cleaned outer element even though it has not been cleaned 6 times. 6. If small holes or thinner parts are found on the element when it is checked by shining a light through it after clean- ing, replace the element. NOTICE When cleaning the element, do not hit or beat it against anything. Do not use an element whose folds, gasket or seal are damaged. When installing the cover (3), check O-ring (7) and replace it if there are any scratches or damage. 7. Set the cleaned outer element in position, then secure cover (3) with mounting clips (2). 8.

Press the button of dust indicator (1) to return the red piston to its original position. 4-19 CAUTION