97 PERIODIC SERVICE 3. Set the hand throttle lever at the maximum speed position, turn the key switch to start the engine and then reset the throttle lever at the mid speed (around 1500 rpm) position. If engine doesn't start, try it several times at 30 second intervals. B Replacing Fuse The tractor electrical system is protected from potential damage by fuses. A blown fuse indicates that there is an overload or short somewhere in the electrical system. If any of the fuses should blow, replace with a new one of the same capacity. A Do not hold key switch at engine start position for more than 10 seconds continuously. If more engine cranking is needed, try again after 30 seconds.
A Before replacing a blown fuse, determine why the fuse blew and make any necessary repairs. Failure to follow this procedure may result in serious damage to the tractor electrical system. Refer to the "TROUBLESHOOTING" section of this manual or your local KUBOTA Dealer for specific information dealing with electrical problems. 4. Accelerate the engine to remove the small portion of air left in the fuel system. 5. If air still remains and the engine stops, repeat the above steps. B Bleeding Brake System Consult your local KUBOTA Dealer for this service. B Draining Clutch Housing Water The tractor is equipped with a drain plug under the clutch housing.
After operating in rain, snow or if the tractor has been washed, water may get into the clutch housing. Remove the drain plug and drain the water, then install the plug again. ( 1) Water drain plug