SYSTEM / Control System Lift Arm Auto-Leveler Upward Control (Optional) Purpose: To locate the lift arm between the horizon and the highest position Operation: 3. Pressure oil from the main pump flows to the bottom side port of the lift cylinder through the lift arm spool in the control valve, and raises the lift arm. 1. If the SET position of the lift arm auto-leveler upward set switch is selected after the lift arm is located within the allowable location of the lift arm auto-leveler (a’ in the illustration), the signal from the lift arm angle sensor is memorized by MC, and that is the lift arm auto-leveler upward stop location. 4.
When the lift arm angle sensor moves to the lift arm auto-leveler upward stop position, terminal A-25 of MC is hot grounded, and the electro- magnet on the lift arm raise side is unexcited. Thus the lift arm control lever returns to the neu- tral position, and pressure oil from the pilot valve stops flowing to the control valve. NOTE: When the lift arm is outside a’, although the SET position of the lift arm auto-leveler upward set switch is selected, the lift arm auto-leveler upward stop position cannot be set. In case setting was thus unsuc- cessful, or setting in a different position is needed, again set the lift arm auto-leveler upward stop position. 2.
When the lift arm auto-leveler upward switch is turned ON, terminal A-25 of MC is grounded, and excites the electromagnet on the lift arm raise side of the pilot valve. When the lift arm control lever is moved to the lift arm raise detent position (position to pull farther than the raise position), the lift arm control lever is retained by the elec- tromagnet on the lift arm raise side, and pressure oil from the pilot valve is supplied to the control valve. 5. As the lift arm spool in the control valve also re- turns to neutral, the lift arm stops at the lift arm auto-leveler upward stop position. NOTE:
Above the lift arm upward set position, the electromagnet on the lift arm raise side is always excited. NOTE: In case the lift arm angle sensor is abnor- mal, the lift arm auto-leveler upward control is not made. IMPORTANT: In case either the lift arm angle sen- sor or MC has been replaced, make learning control of the lift arm angle sensor. (Refer to the OPERATIONAL PERFORMANCE TEST/Adjustment.) a’ (Lift Arm Auto-Leveler Upward Allowable Setting Range) a (Lift Arm Upward Work Range) Position of Lift Arm Tip Pin Position of Lift Arm Foot Pin T2-1-60