SYSTEM / Hydraulic System Neutral Circuit At neutral of the control lever, pressure oil from the main pump returns to the hydraulic oil tank through the neutral circuit of the control valve. Only when the steering valve spool moves due to the priority valve, pressure oil is supplied to the steering valve. Therefore, the steering valve is not provided with a neutral circuit. (Refer to Priority Valve Circuit in this section.) Single Operation Circuit Pressure oil from the main pump flows to the control valve, and flows to the lift arm and bucket spools. When the steering valve spool moves, the priority valve spool moves leftward, and pressure oil from the main pump flows to the steering valve.
(Refer to Priority Valve Circuit in this section.) T2-3-6