SYSTEM / Hydraulic System Charging Block Circuit Charging block is installed in order to supply pressure oil from the pilot pump preferentially to the service brake circuit and distribute to other pilot circuits as well. When the engine is started, oil from the pilot pump is delivered to the charging block. At this time, when the amount of accumulated pressure of the service brake accumulators is low, the relief valve is closed. In this case, only pilot pressure is applied to port B of the priority valve. As both pilot pressure and the spring force are applied to port A, the priority valve moves rightward and controls pressure oil to flow further.
Pressure oil from the pilot pump flows to the service brake circuit through the check valve, and accumulates the service brake accumulators. (To be continued to T2-3-16) NOTE: The spring of the priority valve is adjusted so that the priority valve is not completely closed. Although the priority valve is closed completely, a certain amount of pressure oil is being supplied to the circuits downstream. T2-3-14