hitachi — Indicator Light Check Circuit

SYSTEM / Electrical System INDICATOR LIGHT CHECK CIRCUIT (KEY SWITCH: ON) When the key switch is turned to the ON position, terminal B is connected to terminals ACC and M inside the key switch. Current from terminal M of the key switch flows from fuse #8 of fuse box A to terminal 1-2 of the monitor unit. The monitor unit checks the bulbs breakage of warning lamp and indicator by lighting them and also starts the liquid crystal display. Key Switch From Fuse #7 of Fuse Box B Fuse Box A Monitor Unit 1-2 8 Fusible Link Battery Relay To Fuse #7 of Fuse Box B Battery T4GD-02-04-011 T2-4-4