SYSTEM / Electrical System FNR Lever at Operated Position Starting Circuit (Neutral Relay) When the key switch is turned to the START position, terminal B is connected to terminals M and ST inside the key switch. Current from terminal ST of the key switch flows to the neutral relay. Current from terminal M of the key switch flows to fuse #8 of fuse box A and excites the battery relay. By exciting the battery relay, the battery power flows to terminals B of the starter motor and the starter relay. At this time, when either of the FNR lever or the FNR switch is in the forward or reverse position, terminal A-27 of MC is connected to the ground and the neutral relay is excited.