SYSTEM / Electrical System CHARGING CIRCUIT (KEY SWITCH: ON) When the engine starts and the key switch is released, the key switch returns to the ON position. Terminal B is connected inside the key switch to terminals ACC and M with the key switch ON. Current from terminal M of the key switch excites the battery relay through fuse #8 of fuse box A. When the engine rotates, the alternator begins generating electricity. Current from terminal B of the alternator flows to the battery through the battery relay and charges the battery.
Current from terminal L of the alternator flows to terminal 2-2 of the monitor unit as a signal that the alternator begins generating and the monitor unit turns off the alternator indicator, and also flows to terminal C-8 of ICF and terminal A-3 of GPS in order to record history data of the engine operation time. T2-4-12