hitachi — Serge Voltage Prevention Circuit

SYSTEM / Electrical System SURGE VOLTAGE PREVENTION CIRCUIT When the engine is stopped (key switch: OFF), current from terminal M of the key switch is stopped and the battery relay is turned OFF. Although the key switch is turned OFF, the engine does not stop immediately due to inertia force so that the alternator continues to generate electricity. As the generating current cannot flow to the battery, surge voltage arises in the circuit and failures of the electronic components, such as the controller, possibly cause. In order to prevent the occurrence of surge voltage, the surge voltage prevention circuit is provided.

When the alternator is generating electricity, generating current from terminal L of the alternator flows to terminal 2-2 of the monitor unit. The monitor unit connects terminal 2-10 to the ground. Current flows through the load dump relay exciting circuit and the load dump relay is turned ON. Accordingly, although the key switch is turned OFF while the engine is rotating, battery current continues to excite the battery relay through the load dump relay. In addition, the battery relay is turned OFF in ten seconds after the alternator stops generating of electricity. T2-4-16