SYSTEM / Electrical System ENGINE STOP CIRCUIT When the key switch is turned from the ON position to the OFF position, the signal current indicating that the key switch is ON stops flowing from terminal M to terminal #39 of ECM. ECM unexcited the fuel injection solenoid valve and the engine is stopped. The ECM relay is excited for 30 seconds after the key switch is OFF by the timer function. Thus, current flows to terminals #3 and #4 of ECM, and ECM is kept ON. After 30 seconds, the timer stops and ECM is turned OFF.
Key Switch Fuse Box A From Fuse #7 of From Fuse #9 of Fuse Box B Fuse Box B From Fuse #15 of 8 7 Fuse Box B Diode Diode To Fuses #7, #9, #15 of Fuse Box B ECM Relay 3 4 39 Fuse (120A) Fuel Injection Solenoid Valve Fusible Link Battery Relay ECM Battery T4GD-02-04-018 NOTE: The illustration shows the current flow when the timer is working with the key switch OFF. T2-4-18