hitachi — Regulator

COMPONENT OPERATION / Pump Device Control by Pump Control Pressure Decreasing Flow 1. When the control lever stroke is reduced, pressure difference (difference between pressure Pi1 and Pi2) arising at the flow control valve in the control valve is larger. 2. Pump control pressure Pi1 pushes spool 1 (3) and spool 1 (3) moves toward the arrow. 3. Therefore, primary pilot pressure Pg is led to servo piston 1 (10). 4. As there are two servo pistons 1 (10), swash plate (11) tilts toward the flow decreasing direction. 5. Movement of swash plate (11) is transmitted to sleeve 1 (2) through feedback lever link (13). Sleeve 1 (2) moves toward the movement of spool 1 (3). 6.

Pilot primary pressure Pg to servo piston 1 (10) is blocked when sleeve 1 (2) has moved the same distance as spool 1 (3). Therefore, servo piston 1 (10) stops and the flow decrease is completed.

Flow (Q) 0 Pump Control Pressure (Pi1-Pi2) ST Pd1 Displacement Angle T4GB-03-01-006 1 - Spring 10 - Servo Piston 1 2 - Sleeve 1 11 - Swash Plate 3 - Spool 1 12 - Servo Piston 2 4 - Piston 13 - Feedback Lever Link Pd1 - Own Pump Pressure Pi1 - Pump Control Pressure 1 ST - Torque Control Pressure Pi2 - Pump Control Pressure 2 T - Returning to Hydraulic Oil Tank Pg - Primary Pilot Pressure (From Pilot Pump) T3-1-8 3 2 1 4 Air Pi1 T Vent Pi2 Pg T T 13 10 12 Increase Decrease 4 T 13 10 12 Increase Decrease