hitachi — Regulator

COMPONENT OPERATION / Pump Device Increasing Flow 1. When the control lever stroke is larger, pressure difference (difference between pressure Pi1 and Pi2) arising at the flow control valve in the control valve is reduced. 2. Force due to spring (1) and pump control pressure Pi2 pushes spool 1 (3) and spool 1 (3) moves toward the arrow. 3. Therefore, the circuit of servo piston 1 (10) is led to the hydraulic oil tank. 4. As pilot primary pressure Pg is always applied to servo piston 2 (12), swash plate (11) tilts toward the flow increasing direction. 5. Movement of swash plate (11) is transmitted to sleeve 1 (2) through the feedback lever link (13).

Sleeve 1 (2) moves toward the movement of spool 1 (3). 6. When sleeve 1 (2) has moved the same distance as spool 1 (3) servo piston 1 (10) is not connected to the hydraulic oil tank. Therefore, servo piston 1 (10) stops and the flow increase is completed.

Flow (Q) 0 Pump Control Pressure (Pi1-Pi2) ST Pd1 Displacement Angle T4GB-03-01-006 1 - Spring 10 - Servo Piston 1 2 - Sleeve 1 11 - Swash Plate 3 - Spool 1 12 - Servo Piston 2 4 - Piston 13 - Feedback Lever Link Pd1 - Own Pump Pressure Pi1 - Pump Control Pressure 1 ST - Pump Torque Control Pressure Pi2 - Pump Control Pressure 2 T - Returning to Hydraulic Oil Tank Pg - Primary Pilot Pressure (From Pilot Pump) T3-1-10 3 2 1 4 Air Pi1 T Bleeding Pi2 Pg T T 13 10 12 Increase Decrease 4 T 13 10 12 Increase Decrease