COMPONENT OPERATION / Pump Device Increasing Flow 1. When the pump load is reduced, own pump pressure Pd1 lowers. (Pump control pressure (Pi1 - Pi2) remains lowered during an operation.) 2. Load piston (5) and spool 2 (6) are pushed by inner spring (8) and outer spring (9), and spool 2 (6) moves toward the arrow. 3. Therefore, the circuit of servo piston 1 (10) is connected to the hydraulic oil tank. 4. As primary pilot pressure Pg is always applied to servo piston 2 (12), swash plate (11) tilts toward the flow rate increasing direction. 5. Movement of swash plate (11) is transmitted to sleeve 2 (7) through feedback lever link (13). sleeve 2 (7) moves toward the movement of spool 2 (6). 6.
When sleeve 2 (7) has moved the same distance as spool 2 (6), the openings of spool 2 (6) and sleeve 2 (7) close, servo piston 1 (10) is not connected to the hydraulic oil tank. Therefore, servo piston 1 (10) stops and the flow increase is completed.
Flow (Q) Pressure (P) 0 Pi1 T Air Bleeding Pi2 Pg T 8, 9 Displacement Angle 13 T4GB-03-01-006 5 - Load Piston 10 - Servo Piston 1 6 - Spool 2 11 - Swash Plate 7 - Sleeve 2 12 - Servo Piston 2 8 - Inner Spring 13 - Feedback Lever Link 9 - Outer Spring Pd1 - Own Pump Pressure Pi1 - Pump Control Pressure 1 ST - Pump Torque Control Pressure Pi2 - Pump Control Pressure 2 T - Returning to Hydraulic Oil Tank Pg - Primary Pilot Pressure (From Pilot Pump) T3-1-14 ST Pd1 T 7 6 8 10 12 Increase Decrease 5