hitachi — Regulator

COMPONENT OPERATION / Pump Device Control by Pilot Pressure from Torque Control Solenoid Valve Decreasing Flow 1. Command from the MC (main controller) drives the pump torque control solenoid valve and pump torque control pressure ST enters the regulator. 2. Pump torque control pressure ST acts on load piston (5) by adding to own pump pressure Pd1. 3. Load piston (5) pushes spool 2 (6), inner spring (8) and outer spring (9), and spool 2 (6) moves toward the arrow. 4. Therefore, primary pilot pressure Pg is led to servo piston 1 (10). 5. As there are two servo pistons 1 (10), swash plate (11) tilts toward the flow rate decreasing direction. 6.

Movement of swash plate (11) is transmitted to sleeve 2 (7) through feedback lever link (13). Sleeve 2 (7) moves toward the movement of spool 2 (6). 7. Primary pilot pressure Pg to servo piston 1 (10) is blocked when sleeve 2 (7) has moved the same distance as spool 2 (6). Therefore, servo piston 1 (10) stops and the flow decrease is completed.

Flow (Q) Pressure (P) 0 Pi1 T Air Bleeding Pi2 Pg T Displacement Angle 13 T4GB-03-01-006 5 - Load Piston 10 - Servo Piston 1 6 - Spool 2 11 - Swash Plate 7 - Sleeve 2 12 - Servo Piston 2 8 - Inner Spring 13 - Feedback Lever Link 9 - Outer Spring Pd1 - Own Pump Delivery Pressure Pi1 - Pump Control Pressure 1 ST - Pump Torque Control Pressure Pi2 - Pump Control Pressure 2 T - Returning to Hydraulic Oil Tank Pg - Primary Pilot Pressure (From Pilot Pump) T3-1-16 ST d1 T 7 6 8 10 12 Increase Decrease 5