COMPONENT OPERATION / Control Valve Bottom Side Circuit of Lift Arm and Bucket Relief Operation 1. Pressure at port HP (the front circuit) acts on the shaft through the seat. 2. When the pressure at port HP reaches the set force of spring A, the shaft moves and pressure oil flows to port LP. 3. Consequently, the pressure in the front circuit decreases. 4. If pressure in the front circuit decreases to the set pressure, the shaft is moved by the force of spring A and the oil passage is closed. Make-Up Operation 1. When pressure at port HP (the front circuit) decreases lower than the pressure at port LP (the hydraulic oil tank), the sleeve moves to the right. 2.
Hydraulic oil in port LP flows into port HP and cavitation is prevented. 3. When the pressure at port HP reaches the set pressure, the sleeve is closed by the force of spring B. T3-2-16