COMPONENT OPERATION / Control Valve FLOW RATE CONTROL VALVE The flow rate control valve is installed in the bucket circuit, restricts the circuit during the combined operation and gives priority to operations of the other actuators. Single Operation of Bucket Crowding 1. Pressure oil from the main pump flows through the lift arm spool. 2. Pressure oil from the lift arm spool flows to the bucket spool through check valve 1 and is supplied to the bucket cylinder. Combined Operation of Bucket Crowding and Lift Arm Raising 1. One of pressure oil from the main pump is supplied to the lift arm cylinder through the lift arm spool. 2.
Another of pressure oil from the main pump is supplied to the bucket spool through the parallel circuit. 3. At this time, pressure oil is restricted through the orifice from check valve 2. 4. Pressure oil through the orifice flows to the bucket spool and is supplied to the bucket cylinder. 5. Therefore, as pressure oil to the bucket spool is restricted and more pressure oil is supplied to the lift arm side having higher pressure, both the lift bucket and the lift arm move at the same time.
T4GB-03-02-020 T3-2-22 of Pressure Oil from Pump during Lift pool Operation Check Valve 2 Orifice Check Valve 1 To Bucket Spool Inlet of Pressure Oil from Main Pump in Neutral of Lift Arm Spool ssure Oil from during Lift Operation Check V Orifice Check Valve 1 Check V alve 2 Orifice