hitachi — Electromagnetic Detent

COMPONENT OPERATION / Pilot Valve ELECTROMAGNETIC DETENT The coil for detent is installed at the push rod part of the pilot valve. 1. When one of the control levers is tilted, push rod (2) and plate (8) of the other are pushed upward by the spring force. 2. If the control lever is operated to its stroke end, plate (8) of the other is attracted by coil assembly (10). 3. Adsorbed condition is retained until the coil assembly (10) is unexcited or until attraction is forcefully cancelled by operating the control lever to the other direction. T4GB-03-05-007 2 - Push Rod 8 - P late 10 - Coil Assembly T3-6-6 2 10 8