COMPONENT OPERATION / Charging Block PUMP TORQUE CONTROL PROPORTI- ONAL SOLENOID VALVE (REFER TO THE PILOT CURCUIT IN THE SYSTEM / HY- DRAULIC SYSTEM GROUP.) Pilot pressure supplied to the main pump regulator for the pump delivery flow rate control is controlled by the operation of the pump torque control proportional so- lenoid valve. 1. When there is no signal from MC (Main Control- ler), the spool of the solenoid valve is pushed by the spring. 2. Pilot pressure oil is supplied to port ST in the main pump regulator through port X. 3.
When the signal is transmitted from MC, the spool moves toward the spring in response to the signal value and the amount of pilot pressure oil through port X is lowered. 4. When the signal from MC becomes the maximum value, the spool fully moves toward the spring and pilot pressure oil is blocked by the spool. 5. As port X and port DR2 are connected, pilot pressure oil at port X is lost. Not in Operation of Solenoid Valve To Main Pump Regulator Pilot Pressure Oil T4GB-03-06-009 In Operation of Solenoid Valve Port X Port DR2 Spring Spool (Section U-U) Pilot Pressure Oil T4GB-03-06-010 T3-7-8 Port X Spring