hitachi — Pump Control

SYSTEM / Control System Torque Decrease Control Purpose: To utilize engine output power by changing pump delivery flow rate in response to in- crease or decrease of the engine speed due to traveling load effectively. Operation: 1. When the accelerator pedal is depressed, MC calculates the target engine speed. 2. MC calculates the pump maximum displacement angle most suitable to each time, by using the target engine speed and the signals from the main pump delivery pressure sensor, torque converter input speed sensor and torque con- verter output speed sensor, and transmits the signal to the pump torque control solenoid valve. 3.

The pump torque control solenoid valve transmits pilot pressure according to the signal to the main pump regulator, and controls the pump delivery flow rate. 4. If load applied to the engine becomes large and decreases the actual engine speed below the target speed, the pump displacement angle is decreased and delivery flow rate is decreased. Thus, operation of the vehicle body is improved. NOTE: In case the accelerator pedal becomes abnormal, the backup control of the accel- erator pedal control fixes the engine speed at 1100 min -1 . 5. MC calculates the actual engine speed by re- ceiving the signal from the torque converter input speed sensor. NOTE:

In case the signal from either the main pump delivery pressure sensor, torque converter input speed sensor or torque converter output speed sensor is not transmitted to MC, MC does not make torque reduction control, MC makes pump control by only the standard torque control. NOTE: In case the pump torque control solenoid valve becomes abnormal, neither standard torque control nor torque decrease control is made. T2-1-18 Q P-Q Line Flow Rate Pressure P