hitachi — Transmission Control

SYSTEM / Control System FNR Lever Priority Control Purpose: To smoothen danger-preventive function in forward/reverse operation by giving priority to the signal from FNR lever over the signal from FNR switch Operation: 1. In case the FNR lever is operated while traveling by using the FNR switch, MC disables operation of the FNR switch, and makes forward/reverse control by the input signal from the FNR lever. 2. When operating again by using the FNR switch, the FNR switch is effective again by turning the FNR selector switch ON while both the FNR lever and the FNR switch are at the neutral position. 3.

Until the FNR lever is operated next from that time, MC makes forward/reverse control by the FNR switch input signal. NOTE: In case short-circuiting takes place inside the FNR lever, the transmission is made neutral forcedly, and traveling becomes impossible, which requires towing. However, in case the FNR switch is out of order, traveling by the FNR lever is possible as an emergency measure. NOTE: The FNR switch does not transmit the neu- tral signal. In case of no electric current from the FNR switch, the controller judges that the switch is neutral (N). T2-1-24