SYSTEM / Control System Bucket Auto-Leveler Control Purpose: Automatically to tilt the bucket at a proper angle (horizontal) to start digging when re- turning the bucket to the tilting position Operation: 1. When bucket dump operation is carried out, the bar is located in front of the bucket proximity switch. While the bar passes near the bucket proximity switch, the bucket proximity switch is turned ON. This excites the leveler relay and electromagnet at the bucket tilt side in the pilot valve. 2.
When the bucket control lever is moved farther than the bucket tilting detent position (position to move farther than the tilting position), the bucket control lever is retained by the electromagnet on the bucket tilting side, and pressure oil from the pilot valve moves the bucket spool in the control valve. 3. Pressure oil from the main pump flows to the bottom side of the bucket cylinder through the bucket spool in the control valve, and extends the bucket cylinder. When the bucket cylinder is ex- tended, the bar also passes by the bucket prox- imity switch at the same time. 4. When the bar moves apart from the bucket prox- imity switch, the bucket proximity switch is turned OFF.
As the leveler relay and the electromagnet at the bucket tilt side are unexcited, the bucket con- trol lever is returned to the neutral position. As the bucket spool in the control valve also returns to neutral, the bucket cylinder stops. Consequently, the bucket is kept at the proper digging angle (horizontal). T2-1-54