DOOSAN ŠKODA POWER — DOOSAN ŠKODA POWER Steam Turbine Assembly Manual

Instructions for ST assembly 210 MW Bandel India Document number: S12003-YK09-05MAA-747002 Tylova 57l 31600 Plzeň l Českб Republika area of the bracket with optical leveling. Note: Springs support its necessary to lock in its mounting on the HPSC valve body. Poznбmka: Pružinovou podpěru Lisega je nutnй zaaretovat p ři jejн montбži na tě leso VTRZR ventilu. Work status: Bodies of HPSC valves are set on position ready for the steam piping connecting. Stav pracн: Tělesa VTZRZ ventilů jsou ustavena na pozici a připravena pro připojenн parnнho potrubн. Positioning of bodies of HP Stop & Control valves (HPSC): Ustavenн těles Rychlozбvěrnэch a regulačnнch ventilů (VTRZR):

Assembly of control valves Montбž regulačnнch ventilů Date: 12.11.2013 Page 216 / 278 Prepared: O.Baroch Last Revision: Approved: P.Lešetickэ