D 2011 Fuel system TD 2011 W 07-06-01 ●Bleed the suction chamber of the injection pump. ●Activate high-pressure hand pump until fuel emerges at the locking screw (1). 1 ●Tighten screw plug (1). 45 Nm 6 © 39192-1 ●Actuate the high-pressure hand pump constantly. The fuel must flow evenly out of the over - flow pipe. ●Turn the crankshaft slowly and evenly in the direction of the arrow (engine direction of rotation) until the fuel flow turns to drops. As soon as the fuel flow becomes drops, the start of injection has been reached. © 47635-2 ●Read start of injection on the degree scale. Start of injection: Note specifications on the company plate.
The start of injection must be set if it does not match the specifications. The start of injection of other injection pumps should be checked using this method. Calculate the ignition UDC of each cylinder with the degree scale. Observe ignition interval. © 39195-1 © 01/2009 OBJ_DOKU-23506-001.fm 7/12 Cylinders Ignition interval 2 180° 3 120° 4 180°