75 REGULAR CHECKS AND MAINTENANCE WORK 4. Retighten the drain plug. B Hydraulic Oil Check with Hydraulic Hammers The hydraulic oil change after 1000 operating hours in the operator's manual is based on normal excavator work. Following inspection measures are valid when hydraulic hammers are used: 1. Changing and filling up of hydraulic oil (1) The hydraulic oil must be changed more often when hammers are used because the machine is subject to harder conditions than normal excavating work. (2) Use only the recommended oils mentioned in the operator's manual when changing or filling with oil. (3) When filling up oil, do not mix oils of different makes. 2.
Changing the return filter and oil (1) The filter must be changed more often because of contamination resulting from the frequent assembly and disassembly of the hoses. (2) Use the correct replacement filter. (3) Oil change according to operating hours. (1) Oil filling plug (2) Pin (3) Suction filter (4) Drain plug 5. Fill oil through the oil filling opening on the top side of the tank. 6. Let the engine run and operate the boom, arm, bucket and boom swing device. Then bring the boom to the highest position, pull the arm, bucket inward and boom swing left end. 7. Fill oil again up to the center of the gauge. 8. Install the hydraulic tank cover and tighten the oil filling plug.
Hydraulic oil Return filter Suction Filter Normal excavator work every 1000 Hrs. every 1000 Hrs. (250 Hrs. after first operation) every 1000 Hrs. Hammer work portion 20% every 800 Hrs. every 800 Hrs. 40% every 400 Hrs. every 400 Hrs. 60% every 300 Hrs. every 300 Hrs. more every 200 Hrs. every 200 Hrs. Hydraulic oil volumes Hydraulic tank 45 L Whole oil volumes 79 L