Terex TL160 — 8.2 Table of faults

Trouble-shooting 8 8 Trouble-shooting Operating problems may occur due to irregular maintenance, the use of unsuitable materials, or incorrect handling of the machine. The following Table presents a summary of a range of problems and their possible causes. During the warranty period, malfunctions must be dealt with by your responsible Service Agent or a specialist workshop. If a problem can only be eliminated through repair, then your responsible Service Agent must be called in. 8.1 Engine All faults in the diesel engine must be examined as described in their specific Perkins Engine Operating Instructions 1104C-44T. 8.2 Table of faults Tab.

31 Table of faults 105/112 TL160 Operating Manual 12.9.08 Version 1.0 Possible cause Remedy No steering movement Oil supply to pump interrupted Check and repair suction line Hydraulic pump damaged Repair or replace Priority valve damaged Remedy fault (call Service Agent) Hand metering unit damaged Remedy fault (call Service Agent) Steering cylinder damaged Repair Mechanical fault Repair Insufficient performance of service brake Wear in brake discs Adjust or repair (call Service Agent) Brake control system damaged Repair or replace (call Service Agent) Mechanical fault Repair (call Service Agent) Insufficient performance of parking brake Wear in brake discs Re-adjust or repair Hydraulic fault in brake actuation Replace and/or re-adjust Hydrostatic travel drive without neutral position Switch for travel direction damaged Replace / repair Solenoids of valve damaged Replace / repair Neutral position incorrectly adjusted Check / re-calibrate (call Service Agent) Internal damage to travel pump Replace travel pump Excessive engine idling Re-adjust engine idling