MAINTENANCE PROCEDURE 4.8.10 MANUTENZIONE OGNI 2000 ORE Carry out these operations together with those to be performed EVERY 50, 250, 500 and 1000 HOURS. 4.8.10.a CHANGING THE COOLANT q The coolant must be replaced every 2000 hours of ope- ration or every 2 years, whichever occurs first. q Soon after the machine has been stopped the coolant is very hot and under pressure and it may cause serious burns; let the engine cool down until it reaches approxi- mately 40-45єC before changing the coolant. q Slowly loosen the radiator cap, in order to release the residual pressure.
q Oils, filters, coolants and batteries are considered spe- cial waste and must be collected and disposed of ac- cording to the anti-pollution regulations in force. IMPORTANT q The change of the permanent coolant does not require the descaling of the circuit. Before changing the coolant, lift the loader arm and secure it with the safety lock (see "3.1.1 LOADER LOCKS"). 1 - Raise the engine hood (see "3.5.1 ENGINE HOOD") and open the rear panel (see "3.5.2 REAR PANEL"). 2 - Loosen and remove the upper cap (1) of the radiator. 3 - Open the drain cock (2) of the radiator, remove the drain plug (3) positioned on the engine block and let the fluid flow out. Use a 17 mm hexagon spanner.
While the fluid flows out, drain the coolant tank (4). 4 - Close the drain cock (2), the plug (3) on the engine block and fill the radiator with new fluid (see "4.3 FUEL, COO- LANT AND LUBRICANTS"). 5 - Start the engine and let it idle for a few minutes; check the level again and if necessary top up before putting back the upper cap (1). 6 - Fill the tank (4) until reaching the maximum level. 7 - Close the rear panel and the engine hood. 200 CAUTION WARNING