16. TROUBLESHOOTING 16.4 OTHER TROUBLE 16.4.1 ELECTRICAL SYSTEM ( ): Always contact your Komatsu distributor when dealing with these items. In cases of abnormalities or causes which are not listed below, please contact your Komatsu distributor for repairs.
2-95 Problem Main causes Remedy ‡ Defective wiring ‡ Defective adjustment of alternator Lamp flickers while engine is running best tension For details, see EVERY 250 HOURS SERVICE Charge level monitor does not go out even when engine is running ‡ Defective alternator ‡ Defective wiring (‡ Replace) (‡ Check, repair) Abnormal noise is generated from alternator ‡ Defective alternator (‡ Replace) Starting motor does not turn when starting switch is turned to ON ‡ Defective wiring ‡ Insufficient battery charge (‡ Check, repair) ‡ Charge Pinion of starting motor keeps going in and out ‡ Insufficient battery charge ‡ Charge Starting motor turns engine sluggishly ‡ Insufficient battery charge ‡ Defective starting motor ‡ Charge (‡ Replace) Starting motor disengages before engine starts ‡ Defective wiring ‡ Insufficient battery charge (‡ Check, repair) ‡ Charge Pre-heating monitor does not light ‡ Defective wiring ‡ Defective heater relay ‡ Defective monitor pilot lamp (‡ Check, repair) (‡ Replace) (‡ Replace) Engine oil pressure monitor lamp does not light up when engine is stopped (starting switch at ON position) ‡ Defective monitor ‡ Defective wiring, defective sensor (‡ Replace) (‡ Check, repair, replace) Battery charge monitor lamp does not light up when engine is stopped (starting switch at ON position) ‡ Defective wiring ‡ Defective monitor (‡ Check, repair) (‡ Replace) Outside of electrical heater is not warm when touched by hand ‡ Defective wiring ‡ Disconnection in electrical heater ‡ Defective operation of heater relay switch (‡ Check, repair) (‡ Replace) (‡ Replace)