Komatsu — 16.4 OTHER TROUBLE

16. TROUBLESHOOTING CHASSIS continued (16.4.2) 2-98 Problem Main causes Remedy Hydraulic system Lack of lifting power for bucket Bucket takes time to rise ‡ Lack of oil ‡ Clogged hydraulic tank filter ‡ Add oil to specified level. See EVERY 100 HOURS SERVICE ‡ Replace filter. See EVERY 2000 HOURS SERVICE Excessive bubbles in oil ‡ Low quality oil being used ‡ Oil level is low ‡ Air in oil line ‡ Replace with good quality oil ‡ Add oil to specified level. See EVERY 100 HOURS SERVICE ‡ Bleed air. See WHEN REQUIRD Hydraulic pressure is low ‡ Oil level is low and pump is sucking in air ‡ Add oil to specified level. See EVERY 100 HOURS SERVICE Then bleed air.

See WHEN REQUIRD Movement of cylinder is irregular ‡ Oil level is low ‡ Oil leakage the inside cylinder ‡ Add oil to specified level. See EVERY 100 HOURS SERVICE