24. SERVICE PROCEDURE 24.2.12 CHECK AIR CONDITIONER (IF EQUIPPED) Check levels of refrigerant (gas) Check twice a year, in spring and autumn. WARNING If the liquid gets into your eyes or on your hands, it may cause loss of sight or frostbite, so never loosen any part of the refrigerant circuit. Operate the cooler of the air conditioner for 5 – 10 minutes, then touch the high pressure portion and low pressure portion of the compressor (or high pressure hose and low pressure hose joint) by hand. At the same time, inspect the flow of refrigerant gas through the sight glass to check the gas level. Please contact your Komatsu distributor for this inspection.
The sight glass is installed to the receiver on the right side of the air cleaner. Operating the air conditioner off season To lubricate each portion of the compressor of the airconditioner during the off-season, operate the airconditioner for 3 – 5 minutes once a month. Be sure to idle the engine at low speed for this purpose. 3-36 Cooler condition Normal Abnormal Temp. of high and low pressure pipes. High pressure pipe is hot. Low pressure pipe is cold. Clear difference in temperature High pressure pipe is warm. Low pressure pipe is cold. Little difference in temperature Almost no difference in temperature between high and low pressure pipes. Sight glass Almost transparent.
Any bubbles disappear if the engine speed is raised or lowered. Bubbles are always flowing. Sometimes becomes transparent, or white bubbles appear. Misty substance is flowing. Connections of pipes Properly connected Some parts dirty with oil. Some parts very dirty with oil. General condition of cooler Coolant level correct, no abnormalities. Ready for use. May be a leak somewhere. Call service repair shop for inspection. Almost all coolant has leaked out. Contact service repair shop immediately.