Komatsu — OTHER TROUBLE

. OPERATION TROUBLESHOOTING OTHER TROUBLE 3 - 163 ELECTRICAL SYSTEM ( ) : Always contact your Komatsu distributor when dealing with these items. In cases of problems or causes which are not listed below, contact your Komatsu distributor for repairs.

Problem Main causes Remedy Lamp does not glow brightly even when the engine runs at high speed Lamp flickers while engine is running Charge lamp does not go out even when engine is running Defective alternator Defective wiring ( Replace) ( Check, repair) Abnormal noise is generated from alternator Defective alternator ( Replace) Starting motor does not turn when starting switch is turned to ON Defective wiring Insufficient battery charge ( Check, repair) Charge Pinion of starting motor keeps going in and out Insufficient battery charge Charge Starting motor turns engine sluggishly Insufficient battery charge Defective starting motor Charge ( Replace) Starting motor disengages before engine starts Defective wiring Insufficient battery charge ( Check, repair) Charge Preheating pilot lamp does not light up (When the engine water temperature is below -20°C) Defective wiring Defective timer Defective monitor Disconnection in glow plug ( Check, repair) ( Replace) ( Replace) ( Replace) Air conditioner does not work properly Blown fuse Insufficient battery charge Defective air conditioner switch Defective blower switch Defective compressor ( Check, repair) Charge ( Replace air conditioner switch) ( Replace blower switch) ( Replace) Blade does not pitch when pitch operation is carried out (dual tilt specification machine only) Defective wiring Defective switch Defective solenoid valve ( Check, repair) ( Replace) ( Replace)