. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE 4 - 23 5. After draining the w ater, close drain valve (4), f ill with cit y water until t he radiator is full, then start the engine and run at low the radiator is filled with water, start the engine, run at start the engine idling. 6. When low id ling, raise th e water temperature to at least 90 °C, then C, then run th e engine for approx. 10 minutes. 7. Stop t he engine, o pen drain v alve (4), and dr ain the wa ter. 8. After draining the w ater, clean the c ooling syst em with cl eaning agent . For th e cleaning m ethod, see the i nstructions for the cl eaning agent . 9. Close drain valve 10.
Repla ce the corro sion resisto r, the n open val ve (1). rrosion r For d etails of the "REPLACE method of replacing the co esistor, see CORROSION RESISTO R CARTRIDGE (PAG resist E 4-71)". (Only machines equipped with corrosion or) 11. Fill wi th super cool ant and tap wate r through t he water f iller up to the bottom of th e filler. For d etails of the m ix ratio for s uper coolant an d water, s ee MIX RATI O CHART F OR WATER AND SUPER C OOLAN T.