. MAINTENANCE SERVICE PROCEDURE CLEANING OUTER ELEMENT NOTICE Before and after cleaning the element, do not leave or keep it in direct sunlight. holders (2), then remove cover (3) and take out 4 - 26 1. outer eleme NOTICE Never r emove t he inner el emen t (5). It will allow dirt to e nter and cause failure of the en gine. rewdriver or other tool. Do not use a sc rewdriver or other tool 2. Hold the out er elemen t (4), move it carefully up a nd down and to th e left an d right, a nd rotate th e element to the left and right while pulling it out. ing the o uter element, cover the air connector 3.
After remov uter elem insid e the air cleaner body with a clean cloth or ta pe to prevent dirt o r dust f rom entering. 4. Use a brush or cloth to remove all the dirt stuck to cover (3) and the i nside of air clean er body (6) . 5. Direc t dry c ompresse d air (Max . 0.69 MPa (7 k gf/cm2, 99.4 PSI)) from th e inside o f the outer element along its folds. Then direc t the co mpressed air f rom th e outside along t he folds, and agai n from t he inside.