Deutz — Deutz 2011 Workshop Manual Level 3

Drive system W 02-01-07 2011 Check runout z Attach magnetic measuring stand and insert meter. z Apply stylus to the main bearing pin with pre-tension (arrow) and set meter to ”0”. z Turn crankshaft evenly and check shells. 02 26 z Remove magnetic measuring stand and meter. Measure fit bearing width 6 z Set micrometer gauge to 35 mm. z Push the internal measuring device between the test surfaces of the micrometer gauge and set to ”0”. z Measure fit bearing width with internal measuring device between the contact surfaces of the starting rings. z Note the measured value (dimension ”A”). 02 11 02 12 02 13 Note The dimension "A" is required for determining the axial clearance.

0312 1564 - 0138 3/4 © 11/2004 © 39180 0 © 39180 0 © 35825 1 © 35825 1 © 39181 0 © 39181 0