Deutz — Deutz 2011 Workshop Manual Level 3

Drive system W 02-03-01 2011 Prepare internal measuring device z Mount probe bolt for the appropriate measuring range in the internal measuring device. z Mount meter with approx. 1 mm pre-tension in the internal measuring device. z Set micrometer gauge to 55 mm. z Balance the internal measuring device between the test surfaces of the micrometer gauge and set the meter at the reversal point of the pointer to ”0”. 6 Note Schematic representation for measuring the con rod bearing shell internal diameter at the points ”a” and ”b” in the levels ”1” and ”2”. z Measure con rod bearing shell internal diameter with internal measuring device.

Insert internal measuring device between the con rod bearing shells. z Balance the internal measuring device respectively at the given measuring points and read off the measured value at the reversal point of the pointer. Note - If the values are up to max. 0.015 mm above the bearing tolerances, the con rod can be used further. - If the wear limit is reached, the con rod has to be changed. 02 52 02 53 02 54 0312 1567 - 0138 6/8 © 11/2004 © 36094 1 © 36094 1 a b 1 a b 2 © 37239 0 © 37239 0 © 39329 0 © 39329 0